# Firmware Lifecycle

Warning

It is recommended to update the device in the IDLE mode without receiving and executing any commands from Modbus, Enapter Cloud, Enapter Mobile App or others.

Note

Make sure you have physical access to the device before starting the update process.

After firmware upgrade the electrolyser must be powered off and turn back on.

# Change Log

# New Features

  • UCM firmware version 1.3.0 release.
  • Support for new hardware. EL 2.1 product codes: ELE210535A2AXV04, ELE210508A2AXV04.
  • Support Dryer 2.0/2.1 Metrics in Modbus.
  • Added Factory Settings Reset.
  • Added Force Refilling.

# Bug Fixes

  • Fixed MAC address of network card is set to 00:80:E1:00:00:01.
  • Fixed MAINTENANCE MODE ON in Error mode is not possible using Enapter Mobile Application.
  • Fixed ROLLBACK VOLATILES after WRITE VOLATILE VARIABLES is not possible.
  • Fixed Fan F103A turns off after exit from Maintenance Mode.

# Compatibility Matrix

Please carefully check the compatibility matrix for the 1.3.0 firmware version with the previous version.

Legend:

  • C - fully compatible;
  • NC - not compatible;
  • PC - party compatible, check additional notes.
1.2.3
OTA Upgradable C
Modbus Communication Backward Compatibility C
Configuration C
Rollback C

# Functional Depreciation Statements

  • Warning WS_20 is deprecated. Instead of using it for checking that Electrolyser reached Max Pressure it is recommended to use input register #1200 (4 = Stand-By (Max Pressure)).

# Known Bugs List

The list below contains the most important problems in the firmware and their solutions.

  • Anti-freeze routine bug - In maintenance mode the anti-freeze routine can start even if the electrolyte tank is empty. The absence of water in the tank in such a situation can lead to overheating and damage to the tank. When this occurs, there is a possibility of KOH leakage within the electrolyser during the next refilling of the internal process liquid tank. Please note that this damage will occur only when the device is left powered on in maintenance mode for extended times, without electrolyte, and at low ambient temperatures below 10 °C.

    Solution: Update the firmware to version 1.4.0 or above. Additionally, ensure that the electrolyser is not left unattended when it is in maintenance mode. To update your device, navigate to Device Info -> Firmware and press the Check for Updates button. If you do not see an available update, you can contact our support team at support@enapter.com.

  • The system stops calculation of total produced H2 after 524288.

    Solution: Update the firmware to version 1.6.0 or above. To update your device, navigate to Device Info -> Firmware and press the Check for Updates button. If you do not see an available update, you can contact our support team at support@enapter.com.

  • Electrolyser doesn't stop during Ramp-Up if no more electrolyte left in the tank. The system must reach Steady to start Ramp-Down procedure. This might cause fatal error in case system stays in Ramp-Up and have no water supply because it will not stop production of hydrogen in 80 min timeout and will continue to work even the electrolyte will reach very low level.

    Solution: Update the firmware to version 1.10.1 or above.