# Firmware Lifecycle

Warning

It is recommended to update the device in the IDLE mode without receiving and executing any commands from Modbus, Enapter Cloud, Enapter Mobile App, EL 2.1 Web GUI or others.

Note

Make sure you have physical access to the device before starting the update process.

Warning

Do not power off the device during the firmware update.

Warning

Remove Dryer Control Network before updating the firmware.

Note

If Site has Enapter Gateway it needs to be updated to version 1.8.9 or higher.

# Change Log

# New Features

  • UCM firmware version 1.6.1 release.
  • Support for new hardware. EL 2.1 product codes: ELE210535A2ASV07, ELE210508A2ASV07, ELE210535A2LSV02, ELE210508A2LSV02.
  • Support for new hardware. EL 2.1 product codes: ELE210535A2ASV06, ELE210508A2ASV06.
  • Water min pressure monitoring.

# Bug Fixes

  • Changed check period for membrane failure.
  • Internal improvements.

# Compatibility Matrix

Please carefully check the compatibility matrix for the 1.6.1 firmware version with the previous version.

Legend:

  • C - fully compatible;
  • NC - not compatible;
  • PC - party compatible, check additional notes.
1.6.0
OTA Upgradable C
Modbus Communication Backward Compatibility C
Configuration C
Rollback C

# Functional Depreciation Statements

  • Warning WS_20 is deprecated. Instead of using it for checking that Electrolyser reached Max Pressure it is recommended to use input register #1200 (4 = Stand-By (Max Pressure)).

# Modbus Compatibility

  • Holding register #6018 is used for Start and Stop the Dryer starting from firmware 1.6.0.

  • Input registers #14 (Cabinet (Chassis) Serial Number) and #1000 (Stack Serial Number) are deprecated. Instead use holding registers #4026 (Enapter Chassis Serial Number) and #4376 (Enapter Stack Serial Number).

# Known Bugs List

The list below contains the most important problems in the firmware and their solutions.

  • An issue (opens new window) using WiFi and Windows to access the .local hostname.

    Solution: Use a local ethernet connection to the electrolyser or IP address as a hostname.

  • If the WiFi router power cut happens for a very short period it is possible that one of the devices connected to the MESH network won't be able to connect to the cloud and will have the offline status.

    Solution: To resolve the issue you will need to manually reboot the device. This issue will be fixed in future FW releases.

  • Electrolyser doesn't stop during Ramp-Up if no more electrolyte left in the tank. The system must reach Steady to start Ramp-Down procedure. This might cause fatal error in case system stays in Ramp-Up and have no water supply because it will not stop production of hydrogen in 80 min timeout and will continue to work even the electrolyte will reach very low level.

    Solution: Update the firmware to version 1.10.1 or above.

  • Pump doesn't run when system HALT while Antifrost routine is heating water in the tank.

    Solution: Update the firmware to version 1.10.1 or above.