# Firmware Lifecycle

# Requirements

Note

Before OTA make sure to go through the list below:

  • It is recommended to update the device in the IDLE mode without receiving and executing any commands from Modbus, Enapter Cloud, Enapter Mobile App, Web GUI or others.
  • Make sure you have physical access to the device before starting the update process.
  • Do not power off the device during the firmware update.
  • Remove Dryer Control Network before updating the firmware.
  • If Site has Enapter Gateway it needs to be updated to version 1.8.9 or higher.
  • Dryer connected to DCN/IDCN should be version 3.6.0 or higher, otherwise it won't be possible to connect Electrolysers to IDCN, monitor and control Dryer from Electrolyser Web GUI or Modbus TCP interface.

# Change Log

Note

It is recommended to do Factory Settings Reset after updating to firmware version 3.5.0.

# New Features

  • Ramp-up and Steady states were improved with derating functionality based on the stack voltage. New events Fatal Error FS_12: Insufficient stack current and Warning WS_32: Derating due to voltage were introduced.
  • Serial numbers (23V*) for new stack models support.
  • Default H2 Production Rate can be set using Mobile App and Cloud.
  • Critical events history available in HMI.
  • Critical events history available in Web GUI.
  • Minimum current values were tuned up. Factory Settings Reset is recommended after firmware update from previous versions to respect new changes.
  • New events Warning WX_16: Large temperature discrepancy and Warning WX_72: Electrolyte sensors discrepancy check disabled were introduced.
  • The electrolyte pump control was tuned up.
  • Stack voltage regulation was improved.
  • Inner pressure check was improved to avoid false positives for 35 bar and 8 bar systems.
  • Various improvements and bug fixes in Web GUI.
  • Holding Register #1015 - Flushing was added.

# Bug Fixes

  • Fixed SIF test doesn't need delay after reboot.
  • Fixed every fatal error transit safety board to safe state requiring Factory Settings Reset.
  • Fixed to show the INTERNAL errors on the Enapter Cloud.
  • Fixed electrolyte replacement check can't be disabled.
  • Fixed bug that login to Web GUI works only from second attempt.

# Compatibility Matrix

Please carefully check the compatibility matrix for the 3.5.0 firmware version with the previous version.

Legend:

  • C - fully compatible;
  • NC - not compatible;
  • PC - party compatible, check additional notes.
3.4.1
OTA Upgradable C
Modbus Communication Backward Compatibility C
Configuration C
Rollback C

# Functional Depreciation Statements

None

# Known Bugs List

The list below contains the most important problems in the firmware and their solutions.

  • This version of firmware can cause false positive triggering of FS_12 (Insufficient stack current) event when production rate set to 60%.

    Solution: Use 65% production rate as a minimum production rate until the patch version of firmware will be released.

  • It is an issue (opens new window) using WiFi and Windows to access the .local hostname.

    Solution: Use a local ethernet connection to the electrolyser or IP address as a hostname.

  • DCN may assign an IP address to devices (computers, mobiles) connected to Wi-Fi AP associated with DCN enabled Enapter devices.

    Solution:

    • Delete the DCN from the Enapter Mobile App and create it one more time.
    • If it is possible try to separate the DCN from your main network environment by connecting the DCN to another WiFi AP. It is no need to separate one DCN from another.

Was this page useful?