# Firmware Lifecycle

# Requirements

Note

Before OTA make sure to go through the list below:

  • It is recommended to update the device in the IDLE mode without receiving and executing any commands from Modbus, Enapter Cloud, Enapter Mobile App, Web GUI or others.
  • Make sure you have physical access to the device before starting the update process.
  • Do not power off the device during the firmware update.
  • Remove Dryer Control Network before updating the firmware.
  • If Site has Enapter Gateway it needs to be updated to version 1.8.9 or higher.
  • Dryer connected to DCN/IDCN should be version 3.6.0 or higher, otherwise it won't be possible to connect Electrolysers to IDCN, monitor and control Dryer from Electrolyser Web GUI or Modbus TCP interface.

# Change Log

# New Features

  • FX_13 event triggering improved.
  • VLAN and Static IP Address support for Cloud over Ethernet.
  • Improved roaming between BSSID for Wi-Fi Communication.
  • New event Fatal Error FU_12: Insufficient stack current was introduced.
  • Added Holding Registers: #5602 Modbus Swap Bytes and #5603 Modbus Swap Words.
  • Added possibility to change Modbus word order for variables from network (big-endian) order to little-endian. This variables will affect Modbus only after Reset.
  • Added Input Register: #8006 Gas Sensor Voltage (HT104_in_v).

# Bug Fixes

  • Fixed running SIF Proof-Tests using Modbus TCP (Holding Register #1016) causes the electrolyser to reboot.

# Compatibility Matrix

Please carefully check the compatibility matrix for the 3.7.0 firmware version with the previous version.

Legend:

  • C - fully compatible;
  • NC - not compatible;
  • PC - party compatible, check additional notes.
3.6.1
OTA Upgradable C
Modbus Communication Backward Compatibility C
Configuration C
Rollback C

# Functional Depreciation Statements

None

# Known Bugs List

The list below contains the most important problems in the firmware and their solutions.

  • This version of firmware can cause false positive triggering of FS_12 (Insufficient stack current) event when production rate set to 60%.

    Solution: Use 65% production rate as a minimum production rate until the patch version of firmware will be released.

  • It is an issue (opens new window) using WiFi and Windows to access the .local hostname.

    Solution: Use a local ethernet connection to the electrolyser or IP address as a hostname.

  • DCN may assign an IP address to devices (computers, mobiles) connected to Wi-Fi AP associated with DCN enabled Enapter devices.

    Solution:

    • Delete the DCN from the Enapter Mobile App and create it one more time.
    • If it is possible try to separate the DCN from your main network environment by connecting the DCN to another WiFi AP. It is no need to separate one DCN from another.